Editor-in-chief
Maria Stella Graziani

Deputy Director
Martina Zaninotto

Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali

International Advisory Board Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
☩Howard Morris Australia
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
☩Jill Tate Australia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada


Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano

Responsible Editor
Giuseppe Agosta

Editorial Secretary
Arianna Lucini Paioni
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it



Area soci
Non possiedi o non ricordi la password!
Clicca qui

Articoli con TAG: conta piastrinica

Indagine conoscitiva sulla qualità del referto dell’esame emocromocitometrico
A survey on the quality of the hematological reporting among the Italian laboratories
<p>Introduction: the Working Groups &ldquo;Hematology&rdquo; and &ldquo;Extra-Analytical Variability&rdquo; of the Italian Society of Clinical Biochemistry (SIBioC) promoted a survey investigating the quality of the complete blood count reporting among Italian Laboratories.<br />Methods: the survey included 36 questions and was sent to all the SIBioC members. 251 laboratories participated in the survey.<br />Results: there is a full concordance in reporting the traditional parameters (leukocytes, erythrocytes and platelet count, hemoglobin, hematocrit and the calculated indices, plus the leukocytes differential count), while other relatively new parameters, like the mean platelet volume (MPV) and the platelet distribution width (PDW) are reported by 70% of the laboratories. A low percentage of laboratories (20-30%) do not report the presence of abnormal cell populations, if detected (blasts, immature granulocytes, plasma cells, prolymphocytes and erythroblasts). 70% of laboratories do not report the erythrocyte and leukocyte related parameters available on the new analyzers. Specific reference intervals for gender and age are adopted by 68% of the laboratories, but only 50% have instrument-specific intervals. 83% of the laboratories include interpretative comments in the report, but only in less than half of them these are harmonized according to the recent available recommendations. 83% of the laboratories have a shared document to manage critical values, that are communicated to the requesting physician by 90% of the laboratories.<br />Discussion: activities promoted by the SIBioC Hematology working group to harmonize the hematological report have been effective on traditional parameters reporting with a substantial improvement compared to the 2014 survey. Two issues remain however unresolved: the inclusion of interpretative comments and of the recent available parameters in the report.</p>
Biochimica Clinica ; 17(1)
Contributi Scientifici - Scientific Papers