Editor-in-chief
Maria Stella Graziani

Deputy Director
Martina Zaninotto

Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali

International Advisory Board Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
☩Howard Morris Australia
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
☩Jill Tate Australia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada


Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano

Responsible Editor
Giuseppe Agosta

Editorial Secretary
Arianna Lucini Paioni
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it



Area soci
Non possiedi o non ricordi la password!
Clicca qui

BC: Articoli scritti da M. Mion

Specifiche di qualità, terminologia e definizione dei metodi di misura delle troponine cardiache Ie T
Quality specifications, terminology and definition of the methods for the measurement of cardiac troponins
<p>All guidelines recommend that cardiac troponin I (cTnI) and T (cTnT) should be considered the preferred biomarkers for the differential diagnosis of acute coronary syndrome (ACS), and also that the 99th upper reference population limit value for cardiac troponins should be measured with an imprecision &le;10 CV%. However, only after the year 2006, some cTn methods showed analytical performances in accordance with the quality specifications required by guidelines. The cTn methods with the best analytical performances (currently named &ldquo;high-sensitivity&rdquo; methods) should be preferred for the early diagnosis of ACS and also for risk stratification of cardiovascular disease both in general population and cardiac patients. The most recent international guidelines recommend that two basic criteria are needed to define the characteristics required for cTn immunoassays in order to be defined as &ldquo;high-sensitivity&rdquo; methods. The first criterion is that the total imprecision (CV) at the 99th percentile value should be &le;10%. The second criterion is that these methods should measure cTn concentrations at least in 50% (and ideally &gt;95%) of both healthy adult men and women with value above the assay&rsquo;s limit of detection. The aim of this SIBioC document is to discuss some critical aspects related to definition of &ldquo;high-sensitivity&rdquo; cTn methods, including: analytical performance, pathophysiological interpretations, and clinical relevance of &ldquo;high-sensitivity&rdquo; cTn assays with particular attention to routine practice of clinical laboratories in Italy, recommending the use of an accurate terminology to avoid the usage of potentially misleading terms.</p>
Biochimica Clinica ; 42(4) 335-342
Documenti SIBioC - SIBioC Documents
 
Valutazione delle caratteristiche analitiche dei metodi di misura delle troponine cardiache I e T: dalla teoria alla pratica di laboratorio. Documento congiunto del Gruppo di Studio Biomarcatori Cardiovascolari di SIBioC-Medicina di Laboratorio ed Europea
Evaluation of analytical performance of immunoassay methods for cardiac troponin I and T: from theory to laboratory practice. Joint document of SIBioC and European Ligand Assay Society
<p>All the national and international guidelines recommend that cardiac troponins (cTnI and cTnT) should be considered the preferred biomarkers for the differential diagnosis of acute coronary syndrome (ACS), and also that the 99th upper reference population limit (URL) value for cardiac troponins should be measured with an imprecision &le;10 CV%. Indeed, the measurement of the 99th URL of cTnI and cTnT is a very hard analytical challenge due to low biomarker concentrations in healthy subjects. For this reason, only after the year 2006, some manufacturers set up the first new generation of cTnI and cTnT immunoassays with improved analytical sensitivity in accordance with the quality specifications indicated by international guidelines. The most recent international guidelines recommend that immunoassays for cTnI and cTnT measurement, able to completely satisfy these quality specifications, should be defined high-sensitivity methods. These methods should be preferred for early diagnosis of ACS syndrome and also for stratification of cardiovascular risk in both general population and cardiac patients. Therefore, understanding the analytical performance of immunoassay methods for cTnI and cTnT, especially at the low normal concentration range, is critically important for both laboratory professionals and clinicians. The aim of this document is to discuss some theoretical considerations related to the definition of analytical sensitivity, as well as some critical aspects concerning the experimental protocols commonly adopted for evaluation and comparison of analytical performances of cardiac troponin immunossays.</p>
Biochimica Clinica ; 42(2) 155-166
Documenti - Documents