Editor-in-chief
Maria Stella Graziani

Deputy Director
Martina Zaninotto

Associate Editors
Ferruccio Ceriotti
Davide Giavarina
Bruna Lo Sasso
Giampaolo Merlini
Martina Montagnana
Andrea Mosca
Paola Pezzati
Rossella Tomaiuolo
Matteo Vidali

International Advisory Board Khosrow Adeli Canada
Sergio Bernardini Italy
Marcello Ciaccio Italy
Eleftherios Diamandis Canada
Philippe Gillery France
Kjell Grankvist Sweden
Hans Jacobs The Netherlands
Eric Kilpatrick UK
Magdalena Krintus Poland
Giuseppe Lippi Italy
☩Howard Morris Australia
Mario Plebani Italy
Sverre Sandberg Norway
Ana-Maria Simundic Croatia
☩Jill Tate Australia
Tommaso Trenti Italy
Cas Weykamp The Netherlands
Maria Willrich USA
Paul Yip Canada


Publisher
Biomedia srl
Via L. Temolo 4, 20126 Milano

Responsible Editor
Giuseppe Agosta

Editorial Secretary
Arianna Lucini Paioni
Biomedia srl
Via L. Temolo 4, 20126 Milano
Tel. 0245498282
email: biochimica.clinica@sibioc.it



Area soci
Non possiedi o non ricordi la password!
Clicca qui

BC: Articoli scritti da L. Baldin

Troponina cardiaca ad alta sensibilità: risultati preliminari di un confronto tra un nuovo strumento “point-of-care” e i più comuni analizzatori impiegati nei laboratori clinici
High sensitivity cardiac troponin: preliminary results of a new point-of-care analyzer compared with the analyzers routinely used in clinical laboratories
<p>Introduction: cardiac troponin concentration measured using a point-of-care testing (POCT) analyzer could accelerate the management of patients awaiting assessment for suspected acute coronary syndrome without persistent ST-segment elevation in the emergency department (ED).<br />Methods: we evaluated a new high sensitivity cardiac troponin I (hs-cTnI) assay applied to the POCT PATHFAST&trade; (Gepa, Italia). The study of imprecision was carried out using commercial control materials and lithium-heparin plasma pools. The percentages of detectable hs-cTnI values between the Limit of Detection (LoD) and the 99th percentile as declared by the manufacturer were studied in a population of reference donors. The clinical diagnostic performance was evaluated in a population of patients presenting to the ED with chest pain (lithium-heparin plasma samples were collected at admission and 3 hours later), in comparison to the most common methods that measure hs-cTnI in clinical laboratories: Architect PLUS i2000SR, Dimension Vista, Advia Centaur XPT, UniCel DXI 800. Using the gender-specific 99thpercentile as declared from each manufacturer, the percentages of agreement and disagreement for the classification of hs-cTnI results were calculated as well as the Cohen&rsquo;s Kappa values.<br />Results: imprecision: concentration range (CV% range)=14.6-12227.3 ng/L (2.8-9.8%); % of hs-cTnI &gt;LoD and &lt;99th percentile in males and females were 30.0% and 18.5% respectively. The percentage ranges of agreement versus disagreement observed in the clinical study were 76.8-96.3% versus3.7-23.2% respectively, and the corresponding Cohen&rsquo;s Kappa values ranged from 0.532 to 0.864. The prevalence of discordant results was obtained on admission sample (range=59.1-83.3%).<br />Discussion: the observed analytical imprecision was satisfactory while the percentages of subjects with hs-cTnI&gt;LoD and &lt;99thpercentile were lower than those declared by the manufacturer because a limited number of subjects has been evaluated. The clinical performance has shown an overall satisfactory agreement with all the analytical platforms used.</p>
Biochimica Clinica ; 44(2) S059-S066
Contributi Scientifici - Scientific Papers